Economical Glass Scale (Encoder)

< >

Industrial grade grating (thick ruler)

Industrial grade scale FC1 (thick ruler) Measuring length: 50mm to 3200mm Resolution: 0.1 μm, 0.2 μm, 0.5 μm, 1 μm, 5 μm Output signal: 5V TTL square wave, differential output (long line driver), 24V HTL square wave, 24V NPN open collector Operating temperature: 0 - 40 ° C

Download
Industrial grade scale FC1 (thick ruler)
Measuring length: 50mm to 3200mm
Resolution: 0.1 μm, 0.2 μm, 0.5 μm, 1 μm, 5 μm
Output signal: 5V TTL square wave, differential output (long line driver), 24V HTL square wave, 24V NPN open collector
Operating temperature: 0 - 40 ° C

Output waveform:
         TTL Output (Standard)                         Differential output (optional)


Output wiring definition:
 
signal 8-core cable 9 Pin CAN
Remarks
+5 V / +24V red
1
TTL&LD
0 V black
2
TTL&LD
A phase Brown
3
TTL&LD
B phase  yellow
4
TTL&LD
Z phase Orange
5
TTL&LD
Z invert green
6
LD
A is inverted purple
7
LD
B inversion blue
8
LD
Shielding silver
9
TTL&LD

Technical characteristics:
 
Measure the length 50-1000 mm (50mm / file), 1100-3200 mm (100mm / file)
Resolution 0.1μm 0.2μm 0.5μm,1μm,5μm
Accuracy ± (5+L)/200µm, at 20°C
Measure the speed 1m/s(1µm) , 2m/s(5µm)
Operating force less than 5N
Operating Voltage 5Vss ± 5% / 24 V (optional)
Current (Input) max. 35mA
Current (single-phase output) max. 4 mA
Degree of protection IP 40
Operating temperature 0-40°C



Download details
Grating signal commonly used acquisition method:
1. Grating digital display table:
Single axis   Two-axis / three-axis
2. AdoptedJJX3000 (signal transfer box)Connection PLC high speed counter (24V NPN open collector signal input)
3. Direct connection PLC high-speed counting module (5V TTL or 5V differential signal input)
4.Connect PLC high-speed counter(Order a 24V NPN open-collector signal output scale
5. With four multiplier function of the computer counting board 
JJX-6000 (PCI interface, serial communication)