HOME

Hot - line:400-900-8812021-51098812

Draw-Wire Transducer (Potentiometeric, Encoder)

< >

Draw-wire transducer

Measure Stroke: 200,500,750,1000 mm Resolution: 1,0.5,0.2,0.1 mm / pulse Accuracy: +/- 0.1% (FS) +/- 1 pulse

Download

Draw-wire Transdcuer Encoder WED50

Measure Stroke: 200,500,750,1000 mm

Resolution: 1,0.5,0.2,0.1 mm / pulse

Accuracy: +/- 0.1% (FS) +/- 1 pulse


Dimensions:


ELECTRICAL CHARACTERISTICS:
Sensing element
Incremental encoders
Range
200,500,750,1000mm
Resolution
0.1, 0.2, 0.5 or 1 mm / pulse
Accuracy
+/-0.1%FS
Output
AB phase square wave, ABZ square wave
Circuit characteristics
Voltage type, open collector type, push-pull type, linear differential
Operating Voltage
12-24V DC/5V DC
Response frequency
10K -50KHZ
Operating temperature
-10 ~ +60°C
Storage temperature
-20 ~ +80°C
Mechanical properties:
Rope parameters
0.7mm diameter coated plastic cable
Pull rope speed
1M/s
shock
10HZ to 1500HZ,10G
Impact
20G,11ms
Pull rope force
700g
Signal cable
Length 1M, diameter 5mm
Degree of protection
IP65 (housing only)
Selection table:

WED50

Range Resolution Output Circuit characteristics Operating Voltage
Optional:
200/500/
750/1000mm
1:1mm/pulse
05:0.5mm/pulse
02:0.2mm/pulse
01:0.1mm/pulse 
Blank: AB phase
Z: ABZ phase
Blank: voltage type
C: Open collector
PP: push-pull type
L: linear differential
blank:
12-24V DC
5V:5V DC