HOME

Hot - line:400-900-8812021-51098812

Economical Glass Scale (Encoder)

< >

Micro span glass scale

Measuring length: 10, 15mm Resolution: 0.005mm Output signal: 5V TTL square wave Operating temperature: 0 - 40 ° C

Download
Micro span glass scale
Measuring length: 10, 15mm
Resolution: 0.005mm
Output signal: 5V TTL square wave
Operating temperature: 0 - 40 ° C

The FCS1 is a precision small grating measuring system suitable for precision measuring in small measuring ranges, especially for measuring, robotics, medical equipment, precision modern processing equipment. Usually used for continuous thickness measurement FCS1 linear scale shift will be converted into a pulse signal.The number of pulse signals corresponding to the distance moved, the pulse frequency is a reaction speed. FCS1 The body consists of a set of precision linear plain bearings, return springs, glass gratings, LED lighting system components.
The FCS1 output signal is a rectangular square wave. A, B phase difference of 90 ° of the two waveforms, can indicate the moving distance and direction.

FCS1 output signal (when moving to the inside of the scale)


Connection Connector Pin Definitions:

TTL output
signal
9-pin CAN
Power supply +5 V
1
Power supply 0 V
2
Output A
3
Output B
4
Screening
9

Technical Features:
Measure the length 10mm ,15 mm
Resolution 5 μm (electronic subdivision)
Accuracy ± 5 μm
Pitch 20μm
Operating temperature 0-40°C
Maximum measurement speed 0.05 m/s
Spring pressure resistance 2 N
Operating Voltage 5Vss ± 5%
Degree of protection IP 40
Insulation resistance min. 20 MW
Output signal (TTL output) L=max. 0.5V at< 10mA
H=min. 3.5V at> 2.5mA

Dimensions:



Grating signal commonly used acquisition method:

1. Grating digital display table:Single axis   Two-axis / three-axis

2. Direct connection of PLC high-speed counting module (5V TTL or 5V differential signal input)

3. With four multiplier function of the computer counting boardJJX-6000 (PCI interface, serial communication)